# Standing routing authority, part 2 — the four unblocks, then autoroute to completion (rev C5.2g)

GND rip-up, SW/VBST, DIM+ and the local SINK_INT escape are accepted. Everything that stopped you this time is one of four things, and all four are cleared below. Then run the autorouter for the whole board and finish. One report at the end.

**1. "Protected" first-pass copper — unprotect it.** The protection flag on autoRouted traces (the SRC_FB blocker and any other) is a tool artefact, not one of my rules. You are authorised to clear the protected flag on any first-pass trace or via and then delete or re-route it. The only copper I protect is listed in part 1: the seven mains nets, the accepted SW (6 segments) and VBST.

**2. Delete the ANALOG-separation ruleset (the 1.0 mm pair rule, UID 24fde684…).** It is unsatisfiable by construction: R17, R19, R20, R45, C19 and Q1 each bridge an ANALOG net and a DIM net across one 0402/0603/SOT-23 pad pair 0.4–0.6 mm apart, so the rule flags their own pads and the router reports them unroutable (that is your C19:P1 finding, and part of the R16/R18 blockage). Default 0.2 mm applies to those nets from now on; keeping the analog traces away from SW/12V/DIM is a routing target that I check on the Gerbers, exactly as for the mains spacing. Do not re-create it in another form.

**3. Length rules, clarified.** "SETPOINT ≤ 12 mm" means the stub from the hold capacitors C10/C15 to U1 pin 5, not the whole star net; "PWM_DIM ≤ 15 mm" means U5 pin 6 to R11. Both are satisfied by placement; report the two stub lengths and stop treating them as constraints.

**4. Delete the three preserved manual GND stubs** (22cb, 41ef, 7b1e). They are leftovers; the pours connect everything they touched.

## Then, without stopping

5. **Run the autorouter now for every non-GND net** with the rules as they stand after items 1–4 (GND excluded — it is delivered by the pours). Let it use vias freely; the zones and keep-outs already constrain it. Where it leaves opens, rip up locally and re-run or hand-route; you have the authority.
6. **Pours and stitching:** activate P1, P2, P3 as defined; 4 vias at U1 pin 4 (P2 → P1), ≥ 8 under U5 (P3 → P1), one beside each remaining top GND pad; solid connections on the U5 centre pads and the C6/C11 GND pads, thermal relief elsewhere. That closes the 110 GND opens.
7. **Full DRC.** Fix findings by rip-up and re-route. Shorts and clearance errors must be zero; the 11 body-check keep-out rows stay waived.
8. **One report:** airwires (0), DRC summary with coordinates of anything left, the lengths of SW, VIN (C6 → U4 pin 3), the SETPOINT stub, the PWM_DIM stub and DIM+ (J2 → F2 → D1), the filled area of P2, and the list of anything you could not close. Do not send an interim report; do not ask for approval for anything inside this message.