CRYOFLUX TECHNOLOGIES -- COLD LADDER -- HEIGHT AND DENSITY STUDY -- PART 2 BENCH STUDY (Q1-Q4) -- REV C (MERGED, AUDITED) October 27, 2026 (Founder Eastern date) | Double hyphens only | INTERNAL/DEV Authority: Founder "Go Part 2" (Oct 27, 17:11 ET); Founder merge direction (Oct 27, 21:03 ET): "merged between the two benches is fine". Governing: Founder Rulings Rev AW; Scope Rev A; Model Rev G. Supersedes: Rev B (sha d7ef84e3...), which superseded Claude bench Rev A (60fe34eb...) and Chuck bench Rev A (45ed5158...). Neither Rev A is filed separately; this record carries both. Audit: Chuck independent audit of Rev B (Oct 27): custody PASS; arithmetic PASS on Q1-1, Q1-2, Q3-1, Q3-2, Q3-4, Q4-3; CONDITIONAL on Q1 packing and mass, Q2 plate performance, Q3 pressure network, Q4 vendor scale-up and chip count. Rev C applies his five wording precisions (C-1 to C-5) and his closed-loop head note. No number changed. Calculation script: CryoFlux_ColdLadder_HeightDensity_Part2_BenchCalc_RevB_Oct27_2026.py. This study does not amend R-CL13, Slot Class A, the W Band, or any locked image. No performance claim is certified. Release: DEV. Outside only after USPTO filing of the depicted matter AND an executed NCND (D-8). EVIDENCE TIERS [V] primary vendor document [L] published literature (Cold Plate Source Note Rev B; full papers to verify) [D] derived from shown inputs [S] planning assumption, unvalidated [M] modeled target [OPEN] needs supplier, OEM, Flux or physical test. Nothing here is measured on CryoFlux hardware. INPUT AUTHORITY - R-CL9/10/27/28/29: one tray per slot (one OAM plus CPU reference); sealed plate-and-port subassembly; board-side cover and non-air auxiliary heat path; 6 slots per rung (1 switch, 5 compute). Two faces x four rungs = 40 compute plus 8 switch trays. R-CL25: accelerator-only trays permitted. - Slot Class A: 1.5 kW nominal, 1.8 kW peak per compute slot (Sep 20). D-14: MI350X 1.0 kW, MI355X 1.4 kW, Gaudi 3 0.9 kW. CPU 0.1 kW, overhead 0.1 kW, switch tray 0.3 kW [S]. - Tray: 40 mm pitch and thickness, 200 mm deep. Tray envelope by rung [S]: 475 - 2(37.5) - 50 = 350 mm (C1/C6); 400 - 75 - 50 = 275 mm (C2); 325 - 75 - 50 = 200 mm (C3). Exact reference datum unresolved. SOURCES P-1 OCP Accelerator Module (OAM) Design Specification v1.5 (2022, public) [V]: module 102 x 165 mm; board 1.57-3.20 mm; two Molex Mirror Mezz Pro connectors, 5 mm mated stack; for 1RU liquid, stiffener bottom to die top within 13 mm; OAM plus heatsink 2 kg maximum; cold plate surface-to-coolant below 0.05 C/W achievable. Spec power classes 700 W / 350 W; MI355X at 1,400 W exceeds the v1.5 envelope. P-2 PICMG COM-HPC (Embedded Computing Design; congatec / PICMG release) [V]: Server Size D 160 x 160 mm, Size E 200 x 160 mm; congatec Xeon D-2700 Size D modules 65-118 W base power. P-3 AMD Instinct MI355X Platform datasheet LE-92704-00 (10/25) [V]: PG-25; 43 C maximum inlet; 2.1 l/min per OAM; up to 1,400 W; eight OAM on UBB 2.0; other PCIe parts air-cooled by heat sinks in AMD's reference. Not proof that a one-OAM independent tray is an AMD-supported form. P-4 AMD ROCm docs, MI350 Series microarchitecture [V]: 7 Infinity Fabric links per GPU; fully connected 8-GPU node on a UBB8 baseboard. P-5 AMD ROCm blog, CDNA 5 and Helios [V]: 72 MI455X per rack; up to 3.6 TB/s scale-up per GPU; 260 TB/s per rack; UALink over Ethernet; 12 switches in 6 switch trays. P-6 Cold Plate Source Note Rev B [L]: Shahi et al. 2023, PG-25, 1 kW test vehicle, 2 l/min, R = 0.0232 C/W; Heydari et al. 2024, best plate 0.0198 C/W (550 W, 8 l/min loop); quick disconnects and fittings dominate pressure drop. Test vehicle values; not an AMD module rating. ===================================================================================================== Q1 -- TRAY FIT, ARRANGEMENT, CONDUCTION, MASS ===================================================================================================== Method. Board plane = tray depth (200 mm) x tray height. Usable board height = envelope less 10 mm rails and 6 mm edge clearance [S]. OAM lies with its 165 mm side along the depth (25 mm left for the backplane connector zone). Vertical need H = OAM + CPU module + interconnect spacing + cold plate features + tolerances, less any overlap a CAD nest allows. The table uses module outlines only (P-1, P-2); connectors, keep-outs and tolerances can only add. Envelope Usable OAM + COM-HPC Server D (262) OAM + COM-HPC Client C (222) OAM-only tray (102) C1/C6 350 334 mm +72 mm FITS +112 +232 C2 275 259 mm -3 mm DOES NOT FIT +37 +157 C3 200 184 mm -78 no -38 +82 FINDING Q1-1: the Slot Class A combo tray (one OAM plus one server-class COM-HPC) closes only at today's 350 mm tray. At C2's 275 mm it fails the vertically stacked rectangular outline screen, before connectors and keep-outs [D]. "Does not fit" means exactly that screen (audit C-1). Bench note on rearrangement: within the 200 x 259 mm board plane, no in-plane arrangement of the two outlines closes either: the 160 x 160 COM-HPC leaves 40 mm of depth beside it (OAM needs 102 or 165) and 99 mm of height above it (OAM needs 102). Only redesigned packaging escapes (boards overlapped through the tray thickness, a different host module or a custom carrier), and that needs CAD. C2 survives only by (a) a client-class COM-HPC (lower CPU class; Founder item) or (b) split trays. The 350 mm pass is a screen, not a fit: it still needs the AMD/OEM single-OAM outline, keep-outs, connector heights, retention and mating travel (NDA, G1) and the CAD nest (G2). FINDING Q1-2: split trays (R-CL25) fit easily: an OAM-only tray needs about 102 mm of board height; a COM-HPC Size D host tray fits a 200 mm envelope (+24 mm). Slot use per rung becomes 1 switch + 1 host + 4 OAM [S]. C2 split: 8 rungs x 4 = 32 accelerators per Ladder at about 2.0 m. C3 split: 10 rungs x 4 = 40 accelerators per Ladder at about 2.0-2.03 m (about 25 mm trim, Model G). Cost: CPU-to-accelerator 1:4 instead of 1:1. Xeon D-2700 offers about 32 PCIe Gen 4 lanes [S, verify per SKU], so four OAMs share host bandwidth (x8 each or a PCIe switch). Workload-dependent; Founder item. Counts are conditional on the slot allocation; host lanes, NUMA, memory, power, routing and signal integrity are OPEN, and a client-class host is not automatically workload-equivalent. FINDING Q1-3 (thickness, 40 mm tray): OAM side about 27 mm (carrier 2.4 + 13 stiffener-to-die per P-1 + 12 cold plate) plus a 2-3 mm R-CL27 cover: fits. The COM-HPC side is set by memory: standard RDIMMs (31.25 mm) do not fit; very-low-profile RDIMMs (18.75 mm), SO-DIMMs or soldered memory are required. Design rule to record. Lateral cage span (6 x 40 = 240 mm nominal) must still carry end rails, seals, latches, harnessing, creepage and cooling routing on drawings. FINDING Q1-4 (conduction): parts AMD air-cools in its reference (PCIe interfaces, retimers, voltage regulators, memory) need designed solid conduction to the cold plate, frame or R-CL27 cover in a sealed fanless GN2 rung, each with heat load and allowable component temperature stated. Still dry nitrogen is not a substitute for forced air. Typical part powers are a few watts each [S]; feasible by design, shown in the Flux layout. FINDING Q1-5 (mass and handling): combo tray about 4.7-5.7 kg [S] (OAM about 1.2, COM-HPC 0.5, carrier 0.5, cold plates 0.8 aluminum to 1.8 copper, frame and cover 1.3, couplings 0.4); within the SP-8 5-8 kg range and below the 8 kg shoulder-lift input. OAM-only trays lighter. This is a screening estimate; the governing value is the CAD BOM or a weighed sample. Empty rung about 20 kg [S]; lifting gear sized for 70-80 kg populated [S]. Mass, CG, extraction force and ergonomics go to Flux Q1 (G7). ===================================================================================================== Q2 -- KW PER SLOT: THERMAL AND ELECTRICAL GATES (SEPARATE) ===================================================================================================== A. Inlet cap. MI355X at 1,400 W is specified at PG-25, inlet at or below 43 C, 2.1 l/min per OAM [V]. A 45 C supply to an MI355X slot fails the vendor inlet limit before any resistance calculation. B. Coolant rise [D]: per OAM 10.06 K at 1,400 W (outlet about 53.1 C at 43 C inlet), 7.18 K at 1,000 W; per slot 8.6 K at 1.2 kW (MI350X slot), 11.5 K at 1.6 kW (MI355X slot). C. Lid above inlet by plate resistance R (case-to-inlet basis; P-6 definition to confirm) [D]: R 0.0198: 1,000 W 63 C; 1,400 W 71 C R 0.0232: 66 C; 76 C R 0.035: 78 C; 92 C R 0.05 (P-1 bound): 93 C; 113 C These are test-vehicle analogues, not MI355X lid or junction temperatures: vehicle, interfaces, heat flux and flow differ. Full network: T_j = T_in + Q x (R_fluid + R_plate + R_TIM + R_junction) plus other loads. Without AMD's allowable T_j and the real network, device thermals cannot be passed or failed. FINDING Q2-1: AMD publishes no lid limit. For an ASSUMED 80 C lid the CryoFlux plate needs about 0.026 C/W at 1,400 W or 0.037 C/W at 1,000 W. Published plates (0.020-0.023 C/W) meet the 1,400 W case; the OAM-spec bound (0.05) does not. Design target: R <= 0.025 C/W at 2.1 l/min PG-25 [M]. AMD's inlet cap does not certify any third-party plate. The literature values and the 0.025 target are feasibility screens, not qualified full die-to-fluid values; the paper's reference planes cannot stand in for the full path, and the 80 C lid is hypothetical (audit C-4). FINDING Q2-2: thermal feasibility of 1,400 W is not ruled out by published data; it is not qualified for the CryoFlux plate (unbuilt). Acceptance route: vendor partner data plus a test article (G3). FINDING Q2-3: MI355X-equipped slots require supply at or below 43 C; the W Band upper end (+45 C) stays for other silicon unless the Founder rules band-wide. FINDING Q2-4 (electrical screen, independent of thermals) [D]: MI350X 1.0 + 0.1 + 0.1 = 1.20 kW PASS nominal MI355X 1.4 + 0.1 + 0.1 = 1.60 kW FAIL 1.50 kW nominal by 0.10 Gaudi 3 0.9 + 0.1 + 0.1 = 1.10 kW PASS nominal Options for MI355X: derate the accelerator to 1.30 kW (only if AMD qualifies that operating point); substantiate host plus overhead at or below 0.10 kW total; or qualify a higher slot class (Founder authorization). The 1.8 kW peak is not sustained nominal permission. ===================================================================================================== Q3 -- DEPTH STACK, FLOW, PRESSURE, PUMP ===================================================================================================== Fluid: PG-25 at rho 1,020 kg/m3 and cp 3,900 J/kg-K [S]; properties at test temperature required. FINDING Q3-1 (depth): inside depth about 300-310 mm. Serial need [S]: front clearance 10 + tray 200 + backplane and connectors 18 + tray dry-break couplings 30 + rung manifold 25 + mating receptacles 28 = 311 mm. The stack does NOT close in series (margin -11 to -1 mm). It closes by integration (couplings set into the backplane plane; manifold beside, not behind, the receptacles) or by about +20-40 mm of rung depth. +40 mm per rung makes the two-face Ladder about 0.99 m deep: allocated area 0.832 vs 0.802 m2 (+3.7 percent) [D]. Flux layout decides (G2). FINDING Q3-2 (flow) [D]: 2.1 l/min x 5 compute slots = 10.5 l/min per rung (84 l/min per Ladder) for compute alone; with about 0.5 l/min per switch tray [S], about 11 l/min per rung and 88 l/min per two-face Ladder. MI350X rung heat 6.3 kW gives about 8.6 K coolant rise. Nominal only: separate auxiliary plate paths, bypass and balancing are added once topology is chosen. FINDING Q3-3 (pressure): branch budget about 0.95 bar [S]: cold plate 0.10, tray couplings 0.25, slot vestibule valves 0.10, rung manifold 0.05, rung-to-spine marriage couplings 0.30, spine header and riser 0.15. Couplings are over half, consistent with P-6. These are sensitivity inputs, not predicted losses; coupling selection (OE-2, OE-6) sets the pump. Eureka's 2.1 m/s and 0.5 bar figures are not used (internally inconsistent geometry). FINDING Q3-4 (pump power per Ladder) [D]: P_hydraulic = dP x flow; electrical at an assumed 50 percent pump and drive efficiency, before redundancy: Flow 0.5 bar 0.95 bar (budget) 1.0 bar 2.0 bar 84 l/min 70 / 140 W 133 / 266 W 140 / 280 W 280 / 560 W 88 l/min 73 / 147 W 139 / 279 W 147 / 293 W 293 / 587 W (hydraulic / electrical). Under 1 percent of a 50 kW Ladder at the budget point. Idealized: no pump curve, coupling Cv or network drop is verified, and 0.95 bar is assumed, not a pump spec. Critical series path, parallel balancing and N+1 duty to be modeled (G4). A filled closed loop does not pay elevation as continuous pump head; elevation matters for fill, startup and pressure rating, plus friction and any thermosiphon effect. ===================================================================================================== Q4 -- OPTION B FABRIC RUNG (AND OPTION A MESH) ===================================================================================================== FINDING Q4-1: MI350X / MI355X scale up through 7 Infinity Fabric links in a fully connected 8-GPU node on AMD's UBB8 baseboard (P-4). No switched scale-up domain wider than 8 is published for this generation. Option B's 35-42 accelerator domain is NOT SUPPORTED BY THE PUBLISHED PLATFORM TOPOLOGY of the D-14 reference accelerators; validate with AMD/OEM (audit C-2). On the public record it requires UALink-generation parts (MI400 series / Helios era, P-5). FINDING Q4-2: Option A's in-rung direct mesh with MI350X is also not a standard AMD topology: Infinity Fabric links would cross the rung backplane instead of a UBB8 board. A 5-GPU mesh needs 4 of 7 links per GPU, so link count allows it, but AMD support, protocol access and signal integrity across the backplane are unproven (NDA, G6). Neither option can assume UBB links extend through a passive spine or one fabric rung. FINDING Q4-3 (occupancy) [D]: a fabric rung takes one of 8 rung positions: 7 compute rungs, 35 accelerators, 7 switch trays (-12.5 percent compute). MI350X compute IT 7 x (5 x 1.2 + 0.3) = 44.1 kW plus fabric rung IT power, which is unknown and cannot be taken as zero (switch silicon, retimers or optics, management, cooling). FINDING Q4-4 (switch count): Helios uses 12 switch chips in 6 trays for 72 GPUs at 3.6 TB/s per GPU (P-5). A 40-accelerator domain at the same per-GPU bandwidth scales to on the order of 7-12 switch chips (plane count may hold it near 12) [S] -- a proportional comparator (12 x 40 / 72 = 6.7), not a radix, port, lane or plane design (audit C-3); the Helios switch count is to be tied to an exact AMD technical source. If it holds, one rung's 6 slots put a single fabric rung at or beyond its edge: likely 2-chip trays at reduced bandwidth, or two cavities. Switch chip power, connector and cable bend radius in a 40 x 200 mm slot: no data today. Q4 OPEN pending vendor diagrams and Flux. ===================================================================================================== WHAT PART 2 MEANS FOR THE FOUNDER'S CONFIGURATION RULING ===================================================================================================== 1. C2 (400 mm rung) does NOT work with today's combo tray. It works only with split trays (32 accelerators per Ladder) or a client-class CPU. 2. C6 (today's 475 mm rung, integrated step) keeps the combo tray and 40 accelerators at about 2.3 m; needs the R-CL13 amendment and the slot-height caddy for the upper levels. 3. C3 with split trays (five levels, about 200 mm trays) reaches 40 accelerators at about 2.0 m, at 1:4 CPU-to-accelerator and a 25 mm height trim; five levels add structure and marriage count. 4. All cases need the depth stack resolved, a plate at about 0.025 C/W, and conduction for the auxiliary parts. 5. MI355X needs a 43 C supply and an electrical decision (derate, overhead proof, or new slot class). 6. Option B waits for UALink-generation accelerators; Option A's in-rung mesh needs AMD engagement. Bench lean (not a ruling, not an engineering qualification): C6 near-term (no tray redesign, combo tray as ratified, reach solved by step and caddy), with C3-split carried as the 2.0 m alternative for split-tray workloads. All three candidates go to the Founder (Chuck concurs): C6, C3-split, C2-split (32 accelerators per Ladder). Audit disposition: NOT ratified by this study -- C6 as geometry winner, C2/C3 host configuration, MI355X nominal power change, W Band adjustment, fabric rung realization, or any performance claim. G1-G7 stay open (audit C-5); priority: AMD mechanical and thermal NDA data, CAD nest, thermal test article, pressure network, topology check. ===================================================================================================== CLOSURE GATES (TEST PLAN) ===================================================================================================== G1 OEM/NDA single-OAM mechanical and thermal drawings; PCIe and Infinity Fabric schema. G2 CAD nest for each rung height and the 40 x 200 mm slot: tolerances, latches, service travel, depth integration. G3 As-built plate coupon: PG-25, 43 C, 2.1 l/min, 1,400 W hot spot, heater plus switch and auxiliary loads; measured T_case or T_j and pressure drop. G4 Coupling and full-rack hydraulic network: seal, cycle, ODH, fail-safe, balancing, N+1. G5 Full slot power budget and nominal cap. G6 Option A / Option B communication fit (AMD engagement; UALink generation). G7 Tray and rung weight, CG, extraction force; lift and caddy evaluation. ===================================================================================================== PRECEDENT STAGING (FACTS ONLY, NO LEGAL CONCLUSIONS) ===================================================================================================== Eureka reference leads only: HP "Computing devices with integrated and isolated liquid cooling" (2021/2024); Silicon Graphics International 2015 and HPE 2015 liquid hot-swap systems; Danfoss 2026 quick-connect; Parker twist-to-connect; Sun dry-disconnect. Verify publication numbers, families, claims, priority and jurisdiction before relevance is assessed. Route B-6 to B-9 and D-18 matter into PA-REPORT for counsel facts-only review. PatSnap novelty and FTO outputs are not conclusive. ===================================================================================================== OPEN AND FLAGGED ===================================================================================================== AMD lid and die-to-lid data (NDA); CryoFlux plate performance (test article); Xeon D PCIe lanes per SKU; switch chip power for Option B; coupling pressure-drop data (OE-2, OE-6); fabric rung IT power; Flux board layout for Q1 and the depth integration (after the Oct 29 reload). Founder items: configuration (C6 / C3-split / C2-split); CPU class or split trays; MI355X slot class; 43 C cap per slot or band-wide; R-CL13 amendment if C6. STATUS: Part 2 bench model complete, merged and audited (arithmetic and traceability PASS). Hardware feasibility OPEN. Next: Flux Q1-Q4 after Oct 29; then the study memo to the Founder for the configuration ruling. D-20 held. End.