# REVISION 3 (2026-11-07) — readiness correction; supersedes conflicting historical text below

Capture complete only (64 added TEST parts: original 62 plus C114/C115); no PCB layout, assembly, power-up or measurements. This is not a build/energization GO.

**ERROR corrected:** 18.8 uF × 0.5 = 9.4 uF, which is BELOW, not marginally above, the stated >10 uF SOURCE guidance. 50% retention is an unsupported scenario, not a TDK specification. Qualification is BLOCKED until exact-part bias evidence and applicable tolerance/temperature/aging establish >10 uF effective at 33.6 V. Nominal-only retention would need >53.19%; this is not a qualification margin. C106's 2.35 uF calculation is likewise conditional, not verified capacitance.

TDK primary catalog page https://product.tdk.com/en/search/capacitor/ceramic/mlcc/info?part_no=C3225X7S2A475K200AE lists item description C3225X7S2A475KT***S (matching T003S), but retrieved text supplies no numeric DC-bias value at 33.6 V. The AB characteristic sheet is not used as an exact soft-termination S curve. No curve or retained percentage has been invented.

**Procurement:** ADI primary page https://www.analog.com/en/products/ltc4238.html marks LTC4238 Obsolete. Rochester's primary ADI partner page https://www.rocelec.com/manufacturers/analog-devices confirms lifecycle support, not exact-part inventory. Direct https://www.rocelec.com/search?q=LTC4238 failed retrieval (provider_error / failed fetch); exact-stock confirmation is ACCESS-BLOCKED, NOT confirmed zero stock. Search context surfaced a third-party Partstack claim of 213 Rochester pieces (https://partstack.com/p/analog-devices/ltc4238iufd-pbf/145207496885); this is only an unverified lead, not primary stock confirmation. No purchase/RFQ or substitution performed. Verified genuine exact-part procurement remains open.

Before any build: resolve U101 real UFD24 footprint, exact-part procurement and effective capacitance. Before any power-up: confirm physical SW101 contact mapping/continuity (do not accept the generic diagonal-pad assertion as proof), assembled continuity and all bring-up safety preconditions. No aircraft retained latch or both-battery unplug detector is implemented. Full physical removal of BOTH batteries is already approved as product manual reset; one battery removal, SEL and brownout are not resets. Lab UV reset is not that product reset.

---

# REVISION 2 (2026-11-07) - SUPERSEDES CONFLICTING TEXT BELOW

Status: schematic capture only. Nothing built or measured. No layout. Bench lab PSU only - no batteries, motors or drone. First power-up current limit 0.1 A; maximum test cap 1 A.

## Rev 2 capture changes
- SW101 (KH-6X6X5H-STM): rewired to diagonal pads only - pad 1 = TEST_RST_N, pad 4 = TEST_GND; pads 2 and 3 unconnected. The datasheet drawing labels terminals A-D but has no contact diagram, so the pairing is unverified; diagonal pads of a 4-pad tactile switch are never internally tied, so reset works with either pairing.
- C114, C115 added (TDK C3225X7S2A475KT003S, 4.7 uF 100 V X7S 1210) on TEST_XI-TEST_GND. TEST_XI now has C104/C105/C114/C115 = 18.8 uF nominal, about 9.4 uF if 50% DC-bias loss at 33.6 V is assumed. This does NOT meet the stated LTC4238 >10 uF SOURCE guidance: 9.4 uF < 10 uF. Effective-capacitance qualification is BLOCKED. The TDK bias curve was not retrieved, so this is an assumption, not a verified value. Added startup energy is 0.5 x 18.8 uF x 33.6^2 = 10.6 mJ.
- C106 (TEST_VOUT): 4.7 uF nominal, about 2.35 uF at 50% derating, which is above the LTC4359 1.5 uF minimum.
- TEST_GND tagged Net Type = Ground.

## VDSFB/SOA (bench-conservative)
R107 = 160 kOhm. Internal RVDSFB 90-150 kOhm gives 36-48% VDS gain. The SOA ladder (C110/R114/C111/R115/C112/R116) is sized so the minimum gain (36%) still trips at <=1.55 W continuous Q101 dissipation; higher gain trips earlier. This is a deliberately pessimistic bench model, not a qualified Q101 thermal model. Operator stop: if Q101 case is >70 C on a thermocouple, power off.

## Corrected reverse-current / prebias test (replaces earlier reverse steps)
Purpose: measure U102/Q103 reverse isolation without the main PSU masking or absorbing the current. A bench PSU must never be assumed able to sink current.
1. Main PSU OFF and **physically disconnected from J101**. Put R_IN = 10 kOhm 0.25 W across J101 (TEST_VIN-TEST_GND) as a defined leakage sense load.
2. Prebias supply: a separate isolated PSU set to 24 V, current limit 0.1 A, into J104 (D102 + R109 protect it from backfeed). Insert a DMM in uA range in series with the prebias positive lead.
3. With the channel OFF (J105 fitted), record I_prebias and V(TEST_XI), V(TEST_VIN) with the DMM, referenced to TEST_GND.
4. Reverse current into the input side = V(TEST_VIN)/10 kOhm. Report the measured value with the meter resolution, for example 'less than 1 uA at 0.1 uA resolution'. Never report it as zero.
5. Repeat with COMM enabled (J105 removed, RUN_N grounded) while the main PSU is still disconnected. U102 must keep Q103 off and V(TEST_XI) must stay below the U101 UV threshold (17.87 V min rising).
6. Only then reconnect the main PSU (0.1 A limit) with a series blocking Schottky (>=60 V, >=1 A) and a DMM in its output lead, and confirm that the main PSU never shows negative current.
Stop limits: prebias PSU hits its 0.1 A limit; V(TEST_VIN) >1 V in steps 3-5; any device warm by touch.

## Probing safety (unchanged)
Gate-source nodes (TP on TEST_GATE1/TEST_XI, TEST_GATE3/TEST_VOUT) are floating. Use a differential probe or a battery-powered DMM. Never clip a mains-earthed scope ground there, and never lift protective earth.

## LTC4238 procurement (checked 2026-11-07, no purchase)
- ADI product page: Obsolete.
- DigiKey 161-LTC4238IUFD#PBF-ND: Obsolete, no quantity available (page read via search context only).
- Mouser: Obsolete, not sold, no stock.
- LCSC C3662958: 0 stock.
BLOCKER: no authorized current stock has been verified; this is NOT evidence that no authorized stock exists. Broker claims are not accepted. Do not substitute. A physical build needs verified genuine LTC4238IUFD#PBF, for example via ADI authorized after-market (Rochester Electronics), which was not verified.

## U101 footprint handoff (separate part task)
Part UID 3b0ba966 (LTC4238-UFD, imported from LTC4238-UFD-LIBRARY.ZIP). Current state: placeholder 2.54 mm pads. Missing geometry: the ADI UFD24 4 x 5 mm QFN package (LTC drawing 05-08-1696 Rev A) - 0.5 mm pitch, 24 leads plus exposed pad (pin 25), per the LTC4238 datasheet Package Description page and the library file LTC-UFD-24-1696.pcb, which is not importable. Land pattern must follow the datasheet recommended solder pad layout; exposed pad connection to GND is optional per the datasheet.

## Not in scope (unchanged)
No sequencer, dump/jettison, auto-retry or aircraft safety latch. The manual lab reset is not the aircraft both-battery-removal reset. Product requirements (90 A continuous, 600 A for 5 s, SEL, no MCU) are unchanged and not demonstrated by this prototype.

---

# Board Bring-Up Plan — Bench HSSS Prototype (bench section)

2026-11-07. Applies ONLY to the captured TEST_ bench circuit (U101–U102, Q101–Q104 … see Specification and Build Record). **No measurement has been performed; every result cell below is blank until measured on hardware.** Nothing here qualifies 600 A, transfer, thermal, flight or battery operation.

## 0. Preconditions / gate to start
- U101 needs a real UFD24 footprint and verified-genuine LTC4238 (obsolete; see build record §6). Do not start without both.
- Visual/AOI check; continuity: TEST_VIN↔TEST_GND, TEST_XI↔TEST_GND, TEST_VOUT↔TEST_GND not shorted (>1 kΩ expected because of dividers/bleeder: VOUT≈R108 20 kΩ, XI≈125 kΩ FB divider ‖ VDSFB path, VIN≈184 kΩ divider).
- J105 shunt **fitted** (COMM hard-off). J102 **open** (C107 disconnected). R121 **not fitted**. J106 RUN_N **open**.

## 1. Equipment
- Bench PSU A (main): 0–36 V, CV/CC, set **0.10 A** first. Must NOT be relied on to sink current; add a 1 kΩ / 2 W bleeder across PSU A terminals for every prebias/reverse test.
- PSU B (prebias): **isolated (floating) output**, ≤36 V, current limit ≤20 mA; connects only via J104 (D102 + R109 on board).
- Resistive load (e.g. 100 Ω / 25 W, 47 Ω / 25 W, 39 Ω / 50 W) or electronic load in CR/CC mode ≤1 A.
- DMM (µA range, 0.1 mV resolution), 4-wire for shunt drop if available.
- Oscilloscope with **high-voltage differential probe** for every gate-to-source measurement (TP103/TP104/TP106 vs TP105). Ground-referenced passive probes only on TEST_GND-referenced nodes (TP101, TP105-to-GND, TP107, TP109–TP112) with ground clip on TP108.
- **Never** attach a mains-earthed scope ground clip to TP103, TP104, TP105, TP106 or any floating node. **Never** lift/defeat protective earth.
- SPST switch or jumper wire for RUN_N, RST_N to TEST_GND; thermocouple or IR thermometer on Q101.

## 2. Safety stop limits (abort immediately and remove PSU A output if any is exceeded)
| Condition | Stop limit |
|---|---|
| VIN | > 34.0 V or D101 warm |
| PSU A current with COMM held off | > 5 mA |
| INTVCC (TP112) | < 4.5 V or > 5.5 V |
| Any gate-source (differential) | > 14 V or negative < −0.5 V |
| Q101/Q102/Q103 case temperature | > 70 °C |
| TEST_VOUT with COMM held off and no prebias | > 0.5 V after 1 s |
| Smoke, odour, PSU in CC unexpectedly at step 3–4 | any |

## 3. Step-by-step

### Step 1 — Unpowered checks (default OFF hardware)
Record resistance to TEST_GND of TEST_VIN, TEST_XI, TEST_VOUT, TEST_INTVCC, TEST_COMM (≈0 Ω with J105 fitted).

### Step 2 — First power, COMM hard-off, PSU A 20.0 V / 0.10 A
Apply 20 V to J101. Expect: INTVCC 4.5–5.5 V; UV pin (TEST_UV) = VIN×0.1399 ≈ 2.80 V (above 2.62 V max rising); OV pin = VIN×0.0691 ≈ 1.38 V; TEST_COMM ≈0 V; GATE1/GATE2 at SOURCE; TEST_XI ≈0 V (only leakage); TEST_VOUT ≈0 V; PG low, FLT_N high (≈INTVCC); PSU current < 5 mA (quiescent + 184 kΩ divider ≈ 0.11 mA + controller supply).
Note: at exactly 20.0 V UV rising margin is only 1.3–2.1 V; if UV not asserted, record and stop.

### Step 3 — Release hard-off but keep Q104 inhibit
Remove J105 shunt with RUN_N still open. Expect same as Step 2 (Q104 holds COMM ≈0 V). This proves the default-OFF path through Q104.

### Step 4 — First enable, no load, PSU A 24 V / 0.10 A
Connect RUN_N to TEST_GND. After ≥40 ms, expect: COMM rises; GATE1−SOURCE → 10–14 V; GATE2 follows (HSSS: GATE1>8 V, VDS<2 V); TEST_XI ≈ VIN; U102 enhances Q103, TEST_VOUT ≈ VIN minus ≤30 mV (regulation) at light load; PG high once XI >16.4 V max. Measure gate-source with differential probe (TP103–TP105, TP104–TP105, TP106–TP105). Open RUN_N: channel turns off; record XI/VOUT decay.

### Step 5 — Rail sweep 20 / 24 / 28 / 33.6 V, no load
Repeat Step 4 enable at each voltage. At 33.6 V confirm OV not asserted (OV pin ≈2.32 V < 2.50 V min). Optional: slowly raise to 34.0 V only (never higher) and stop.

### Step 6 — UV threshold check
With RUN_N grounded, sweep VIN down from 24 V at ≤0.1 V/s: record gate turn-off (expected UV falling ≈14.7–16.7 V) and on the way up the turn-on (17.87–18.73 V, plus 40 ms delay).

### Step 7 — Startup into small capacitance
Fit J102 (C107 100 µF). PSU A 24 V / 0.10 A, RUN_N toggled low. Record VOUT rise, inrush on PSU, TMR (TP109) and TMRFET (TP110) peaks. Expect no FLT. Then 33.6 V with PSU limit raised to 1.0 A: inrush bounded by 0.574–0.626 A controller limit (with foldback lower). TMR peak expected ≪ 2.56 V; TMRFET returns to ~0 V.

### Step 8 — Resistive load steps (PSU limit 1.0 A)
Loads at 24 V: 100 Ω (0.24 A), 47 Ω (0.51 A). Measure shunt drop TP101–TP102 (2.4 / 5.1 mV expected), VIN−XI, XI−VOUT, Q101/Q102 temperature. FLT must stay high.

### Step 9 — Native current-limit + SOA-timer fault (energy-limited)
PSU A 24 V / 1.0 A; load 22 Ω (would draw 1.09 A). Expect U101 limits to 0.574–0.626 A (foldback lower as VDS rises), TMR ramps, FLT_N goes low and gates latch off within roughly 0.1–0.5 s. Record time-to-fault, peak Q101 case temperature. Do **not** repeat more than once per minute (Q101 cool-down).

### Step 10 — Manual lab fault reset
With FLT_N low: hold RUN_N open (inhibit), press SW101 (or ground RST_N) ≥1 s, release. Confirm FLT_N high after TMR cool-down, gates stay off while RUN_N open. Then RUN_N low → restarts after 40 ms. Confirm that grounding RUN_N alone, VIN sag above UV, or toggling SEL-like inputs does NOT clear FLT (no auto-retry).

### Step 11 — FET-bad injection (optional, DNP R121)
Power off, fit R121 100 kΩ. PSU A 24 V / **0.10 A**, no load. Enable: VGS1 limited to ≈3.5–7 V (<8 V); expect FLT_N low after ≈128 ms (C113). Record. Remove R121 afterwards.

### Step 12 — Prebias with channel OFF (reverse isolation)
PSU A output OFF but connected with its 1 kΩ bleeder (R_bleed). RUN_N open, J105 fitted. Apply PSU B via J104 at 24 V / 20 mA limit. Measure VOUT (≈ PSU B − D102 drop − I·R109), TEST_XI and TEST_VIN with DMM. **Reverse flow into the main side** = V(TEST_VIN)/R_bleed (resolution: DMM 0.1 mV / 1 kΩ = 0.1 µA) plus V(TEST_XI) recorded. Report measured value with resolution, never “zero”. Expected: XI and VIN stay near 0 V (U102/Q103 off, body diode reverse-biased); leakage limited by Q103 IDSS and U102 OUT pin current.

### Step 13 — Prebias with channel enabled (OUT higher than XI)
PSU A 20 V / 0.10 A; PSU B 28 V via J104. Enable RUN_N. Expect U102 keeps Q103 off while VOUT > XI; PSU B supplies R108 + C106 only; no current into PSU A (verify V across R_bleed vs PSU A setpoint and PSU A current reading ≥0). Then lower PSU B below 20 V: Q103 takes over, record VOUT droop. Stop if PSU A shows any reverse/negative current indication or VIN rises above its setpoint.

## 4. Measurement table (fill on hardware — currently NOT MEASURED)
| # | Quantity | Condition | Expected | Measured | Pass/Fail |
|---|---|---|---|---|---|
|1|INTVCC|VIN 20–33.6 V|4.5–5.5 V| | |
|2|UV pin|VIN 24 V|3.36 V| | |
|3|COMM (OFF)|RUN_N open|<0.1 V| | |
|4|I_PSU (OFF)|VIN 24 V|<5 mA| | |
|5|VGS1, VGS2|ON, 24 V|10–14 V| | |
|6|VGS3 (Q103)|ON, light load|record| | |
|7|VIN−VOUT|0.51 A|record (≤50 mV est.)| | |
|8|UV rising / falling|sweep|17.87–18.73 / ≈14.7–16.7 V| | |
|9|OV rising|≤34 V only|not reached (36.16 V min)| | |
|10|ILIM|22 Ω load, 24 V|0.574–0.626 A (pre-foldback)| | |
|11|t_fault (SOA)|22 Ω load|≈0.1–0.5 s (estimate)| | |
|12|Q101 case peak|step 9|<70 °C| | |
|13|FET-bad delay|R121 fitted|≈128 ms| | |
|14|Reverse current into main|prebias 24 V, OFF|report value ± resolution| | |
|15|PG threshold|XI rising|15.6–16.4 V| | |

## 5. Unresolved / not testable here
- LTC4238 genuine-part availability and U101 footprint (blockers before build).
- Real bench Rth of Q101 and the accuracy of the pessimistic TMR model.
- Any 600 A, multi-device gate, hot SOA, 15 mF, transfer, aux-loss, latch-retention or flight behaviour — explicitly out of scope.